[Frontiers in Bioscience 14, 3712-3723, January 1, 2009] |
|
|
Optimization of magnetic beads for maldi-TOF MS analysis Feng Qiu1, Hong-ying Liu1 , Xue-ji Zhang1,2, Ya-ping Tian1
1 TABLE OF CONTENTS
1. ABSTRACT MALDI-TOF MS is being widely applied to analyze serum samples for the diagnosis of human diseases and for the identification of potential biomarkers. However, different types of magnetic beads afford different purification capability for low abundance proteins and peptides in body fluids. The aim of our study was to establish a proteome fractionation technique for choosing magnetic beads for proteomic analysis in breast cancer research. We used three different kinds of magnetic beads (MB-HIC C8, MB-IMAC-Cu and MB-WCX) to pre-analyze 28 breast cancer patients and 24 healthy control serum samples for proteomic profiling by MALDI-TOF MS analysis. The serum samples purified by MB-WCX group provided the best proteomic pattern .These samples had the most average peak numbers, the highest peak intensities, and the best capturing ability of low abundance proteins or peptides in serum samples. Therefore, we chose MB-WCX as our best magnetic beads to pre-analyze large-scale cancer and healthy control samples. The application of the standardized, pre-analytical serum samples with right type of magnetic bead-based fractionation will decrease variability of proteome patterns in human serum assessed by MALDI-TOF MS. 2. INTRODUCTION Breast cancer is one of the most common malignant tumors in women. For the moment, it is estimated that there are about 1,200,000 women who suffer from breast cancer, and 500,000 have died from breast cancer worldwide (1). And, the incidence of breast cancer is rising. The morbidity and mortality varies in different countries and regions. In China, the morbidity increases more than 3% each year (2). In the long, natural history of breast cancer, there seems early diagnosis appears to be the most appropriate tool to reduce disease-related mortality. At present, there is no early detection and diagnostic test with high sensitivity, specificity, which can be used as a clinical, routine screening tool. Therefore, the need for new biomarkers for breast cancer that can improve early diagnosis, monitoring of disease progression, therapeutic response, and detect disease recurrence is so important (3). Despite the great effort in developing new therapies to improve the survival of breast cancer patients, the results are just modest with the exceptions being select early cancers (4-7). The majority of patients diagnosed with cancer are usually in the late stage of the disease. On the other hand, if these cancers are diagnosed early, and the organs can be confined at the same time, the survival rate will exceed about 85% (4-5).Obviously, with the current therapies and treatments, only the improvements in early detection of cancer will lead to the improvements in cancer survival. So, it is crucial to develop high throughput tests to diagnose cancers earlier. By using mass spectrometry (MS) to generate proteome profiles offers a wide range of possibilities for analyzing biological samples which contain complex mixtures of proteins or peptides. The aim of most profiling experiments is to identify changes in proteomic patterns that are related to a certain disease or clinical changes. Therefore, these patterns might be used to carry early diagnose, offer accurate prognosis, monitor the disease progression or response to treatment, and even to identify which patients are most likely to benefit from particular treatments (8-14). The mass spectrometry instruments that are most commonly used to solve these clinical and biological problems use a matrix-assisted laser desorption, ionization (MALDI) ion source and a time-of-flight (TOF) detection system. In a word, the plate is inserted into a vacuum chamber, and the matrix crystals are struck with pulses from a nitrogen laser. The matrix molecules absorb energy from the laser, transfer it to the proteins causing them to desorb and ionize, and then produce a plume of ions in the gas phase. Mass spectrometric analysis of proteins or peptides is most successful when the samples are analyzed in their purest state. The presence of salts and other small molecules can significantly interfere with the analysis, often with negative effects. Hence resulting suppression of the proteins or peptides of interest can severely reduce the amount of information that can be obtained from an experiment. Desalting and fractionation of the proteins or peptides mixtures are, therefore, required to separate out the compounds of interest. Alternatively, the specific enrichment of target molecules can be isolated based on affinity techniques. Therefore, molecules to be enriched will be absorbed reversibly by a complementary binding substance on an insoluble support. Magnetic beads are the way we do the fractionation. Magnetic beads are micro-particles available with a range of different surface chemistries providing a choice of functionality. These beads are used for sample preparation (for example, serum, plasma, urine, cerebrospinal and peritoneal fluid) before MALDI-TOF MS analysis (15). We can use so many kinds of kits, such as MB-C3, C8 and C18, MB-WCX, WAX, MB-IMAC Fe Cu, MB-IAC Prot G, etc. These are available. The MB-HIC kits are based on super-paramagnetic micro-particles with a highly porous surface functionalized with hydrophobic coatings (C3, C8, C18). The MB-WCX kit is based on super-paramagnetic micro-particles with negatively charged functional groups at their surface enabling cation exchange chromatography. Binding of substances occurs due to reversible adsorption of charged molecules in the solution to immobilized ion exchange groups of opposite charge. The MB-IMAC Fe kit is designed for selective isolation and pre-concentration of phosphopeptides (e.g. protein digests) on the surface of super-paramagnetic micro-particles. Specific interaction between phosphorylated amino acid residues of peptides and magnetic beads is realized via the particle surface functionalized with immobilized polyvalent metal ions (e.g. Fe3+). Using the MB-IMAC Cu Kit, proteins and peptides are separated on the basis of their affinity to Cu ions which have been immobilized by chelation. The immobilized complex has one coordination site available for interaction with amino acid side chains (e.g. -COO-) on the protein surface. The kit MB-IAC Prot G Kit was developed for specific capturing of antigens (e.g. peptides, proteins) from biological fluids based on their affinity to corresponding antibodies. And, we use AnchorChip targets instead of steel targets, because AnchorChip targets produce more homogenous matrix crystallization with better reproducibility of MS spectra than crystallization on steel targets (15). But, choosing the right types of magnetic beads so that we can get as many as possible proteins and peptides for the further proteomics profiling analysis as possible is a major concern. The objective of this study was to assess the feasibility of choosing the correct magnetic bead based on MALDI-TOF MS analysis for breast cancer samples and healthy control individuals. 3. MATERIALS AND METHODS 3.1. Chemicals and calibrators Gradient-grade alcohol and acetone were obtained from J.T. Baker (USA). p.a.trifluoroacetic acid and Ammonium acetate were purchased from Sigma-Aldrich(USA). The peptide calibrator containing Angiotensin Ⅱ, the protein calibrator, and the matrix α-Cyano-4-hydroxycinnamic acid (CHCA) were purchased from Bruker Daltonics GmbH (Germany). For magnetic bead preparations, we used 0.2 mL of polypropylene tubes (8-tube strips) from Axygen Company (USA). Multiple needle sets and polypropylene vacuette without anticoagulants (EDTA, heparin and citrate) were obtained from BD Company (USA). 3.2. Blood samples The blood samples were processed according to a standardized protocol. 1. After sample collection, the vacuette serum (collected in a red-top glass tube containing no preservatives or anticoagulant) were allowed to clot or to sediment at room temperature (about 25℃) for at least half an hour and then centrifuged at 1500g for 15 min. 2. Samples were divided in aliquots of 100�l immediately and frozen at -80℃ refrigerator until use. 3. For proteomic fractionation, samples were thawed at room temperature (about 25℃) for 15 min and processed immediately. 3.3. Patients Serum samples were obtained from a total of 28 breast cancer patients the day before surgery. Breast cancer was histologically confirmed by surgical specimens and pathological validation. Breast cancer patients from our hospital were included from November 2006 till April 2007. The healthy control group consisted of 24 individuals, all from our hospital healthy check center. 3.4. Proteomic fractionation (Isolation of peptides) Serums were subjected to fractionation using functionalized magnetic bead-bases kits (ClinProt Kits, Bruker Daltonics Inc., Fremont, CA). Magnetic beads (particle size, 1 mm) with hydrophobic interaction chromatography C8 (MB-HIC-C8), weak cation exchange chromatography (MB-WCX) were designed for capturing of proteins and peptides from biological samples to obtain specific profiles based on cationic exchange chromatography and immobilized metal-ion affinity chromatography (MB-IMAC-Cu). These were both used according to the manufacturer's protocols. 1. As recommended in the manufacturer's protocol, we added 5 �L magnetic beads to 10�L of a binding solution in a 0.2mL polypropylene PCR tube. 2. Then, we added 5 �L of sample and mixed it thoroughly by pipetting up and down several times. 3. We incubated the tube for 5 minutes. 4. Then, we separated the unbound solution using a magnetic bead separator. 5. After the magnetic bead separation and three times washings, the bound proteins/peptides were eluted from the magnetic beads according to the manufacturer's instructions (Profiling Kit Magnetic beads and Profiling, Bruker Daltonics GmbH, Leipzig, Germany). 6. A portion of the eluted sample was diluted (1:10) in a solution containing CHCA (0.6 g/L in 2:1 ethanol:acetone). 7. Then, 0.5 mL of the resulting mixture was spotted onto the AnchorChip target (Bruker Daltonics Inc., CA) and allowed to air dry for approximately 5 min at room temperature. Generally, each sample for each conditioned experiment was conducted three times. AnchorChip targets produce more homogenous matrix crystallization with better reproducibility of MS spectra than crystallization on steel targets. 3.5. MS analysis (protein profiling) For the proteomic analysis, we used a linear MALDI-TOF mass spectrometer (Microflex; Bruker Daltonics) with the following settings (Table 1): Ionization was achieved by irradiation with a nitrogen laser (λ=337 nm) operating at 25 Hz. Mass spectra were detected in linear, positive mode. Mass calibration was performed with the calibration mixture of peptides and proteins in a mass range of 1000-10000 Da. We measured 3 MALDI preparations (MALDI spots) from each magnetic bead fraction. For each MALDI spot, 400 spectra were acquired (50 laser shots at 8 different spot positions). To increase the detection sensitivity, we usually use higher energy to shoot the spot positions first, and then shoot lower energy to save the spectra. This removes excess matrix with higher laser power before the data acquisition. All signals with a signal-to-noise (S/N) ratio >5 in a mass range of 1000-10000 Da were recorded with the use of the flexControl tool acquisition software (Ver. 2.0; Bruker Daltonics). We used the ClinProTools bioinformatics software (Ver. 1.0; Bruker Daltonics) for proteomic pattern recognition. 3.6. Data processing The MS spectra for peaks of 1,000-10,000 m/z were generated by summarizing 400 laser shots (50 shots at 8 different spot positions). To increase detection sensitivity, excess matrix was removed with 10shots at a laser power of 90% before acquisition of spectra with 50 shots at a fixed laser power of 50%. We exported all unprocessed spectra from the microflex MS in standard format .They covered a domain of 1,000-10,000 Da. To increase the accuracy, the average of eight spots was used to represent one serum sample. To normalize the spectra, we calculated the median intensity of each spectrum and subtracted it from the original spectra. We analyzed the spectra obtained from all the samples by using ClinProTool 1.0 software, did the spectrum processing and generated proteomic fingerprints. Only the spectra obtained from magnetic beads were used in the analysis of this study. Basically, we normalized all spectra to their own total ion count by summation of peak areas and recalibrated using the most prominent peaks, followed by baseline subtraction, peak defining, and calculation of peak intensities, peak numbers and areas. In order to evaluate the degree of variation among different proteome spectra, we first defined the peaks (in general, S/N>5 and minimal peak intensity >1.6 arbitrary units) and carefully checked each corresponding peak throughout all of the spectra. Then, we calculated the mean value of peak intensity, SD and CV (%) for each corresponding peak in our study. The degree of variation on the basis of the whole spectrum was thus determined by calculating the CV values for all of the peaks of the tested spectra. We defined CV >30% or p<0.01 as a significant difference. 4. RESULTS 4.1. Whole quality of mass spectra with three different types of magnetic beads fractionation We compared all the origin mass spectra, including 28 breast cancer patients and 24 healthy control individuals, and drew the conclusion that with the pre-analysis of magnetic bead WCX, it is the best mass spectra. We can see the results from the following pictures (Figure 1). 4.2. The coherence in the two groups- breast cancer group and the normal group With the help of flexAnalysis software (Bruker Daltonics) and related statistical software, we compared the coherence in the two groups, breast cancer group and the control group. The conclusion we reached was almost the same with the whole quality of mass spectra, by using MB-WCX to pre-extract serum samples. The coherence in MB-WCX group was the best in these three types of magnetic beads. 4.3. The capability of seeking proteins and peptides in three types of magnetic beads 4.3.1. Analysis of peak numbers in the mass spectra 4.3.1.1. Breast cancer group As we know, by using different types of magnetic beads to pre-extract our samples, we will get different kinds of proteins or peptides, especially low abundance proteins and peptides. The aim of proteomic pattern analysis of the cancer group and healthy control group is to find the differences in human diseases and seek for new potential biomarkers for early detection and early diagnosis of cancer. So, we hope to get more peaks in the MS analysis, which means we will have more detailed information from serum samples between cancer and healthy control group. At first, we did the comparison of peak numbers in the mass spectra in the breast cancer group after the pre-extraction by three types of magnetic beads, and got the results as follows (Table 2): With the help of paired samples statistics data, we got the correlations in these three paired groups (Table 3). Then, based on the results of paired samples statistics and correlations, we got paired samples test results (Table 4). From the results in paired samples test, we drew the conclusions that the peak numbers in MB-WCX group are fewer than those in MB-Cu group and MB-HIC C8 group. Then, we divided the samples into three paired groups to compare the result. In the paired WCX-Cu group and paired WCX- C8 group, p<0.01, was of great significance. But, little difference was seen in the paired Cu-C8 group. Based on all above data, we drew the following conclusion of these three types of magnetic beads. Peak numbers obtained from each sample are shown along the vertical axis and individual tests are shown on the horizontal axis. (In the picture red designates the MB-WCX group, green designates the MB-Cu group and blue designates the MB-C8 group.) Figure 2 shows the results of the mass spectra information of the breast cancer group. We can easily see that the most peaks we got were from the MB-WCX pre-extraction. By using 28 single samples mass spectra, we did a same sample -different group comparison picture. The results also showed us the same samples in the peak numbers after the pre-extraction of MB-WCX, MB-Cu and MB-HIC C8, as shown in figure 3 below. Each spot delegates one single serum sample in the breast cancer group, and we joined the same sample with three groups' results to see which one was the best choice. The horizontal axis designates the three different groups, and the vertical axis designates the peak numbers we got with each serum sample. 4.3.1.2. Healthy control group Just as we did in the breast cancer group, we conducted the same peak statistics in the healthy control group with 24 serum samples to compare the pre-extraction ability. The results are shown as follows in Table 5, 6 and 7: Using the results shown in Table 5, Table 6 and Table 7, we conducted the paired samples statistics for the healthy control group, and analyzed the correlations and paired sample test. We found that the results were consistent with those in the breast cancer group. We got more peaks using MB-WCX, than MB-Cu, and the least effective was MB-HIC C8. The correlations and the test of two paired were almost the same as the results of the peak statistics. The only difference was that in all the three paired groups, p<0.01, held great significance. With all the data, we performed the peak numbers analysis of healthy control samples in MB-WCX, MB-Cu and MB-HIC C8 groups. Figure 4 shows the obvious results. The result was consistent with those in breast cancer group. The only deviation from breast cancer group was the p value in the paired group MB-Cu and MB-C8, <0.01. This was of great significance. We also did the same sample-three MB group analysis. The result is shown below in Figure 5: 4.3.2. Analysis of peak intensities in the mass spectra 4.3.2.1. Breast cancer group By using the flexAnalysis software and relative statistic software, we analyzed the total peak intensities in the 28 breast cancer samples, and we got the peak intensities statistics shown in see Table 8. Then with the statistics of peak intensities, we got the samples correlation data, and found the results shown in Table 9. Finally, we did the paired samples test and drew the conclusion shown Table 10 and we performed the peak intensities analysis pictured in Figure 6 and Figure 7. In Figure 6, the horizontal axis shows three different MB groups and the vertical axis designates the peak intensities in each serum sample. Red designates the MB-WCX group, green designates the MB-Cu group, and blue designates the MB-C8 group. From the results in Figure 6 and Figure 7, we learned that the peak intensities in MB-WCX group were the highest of these three groups. The paired results in MB WCX-Cu group and MBWCX-C8 group, p<0.01, was of great significance. However, there was no significant difference between MB Cu and theC8 group. 4.3.3.2. Healthy control group We did the same analysis of 24 healthy control serum samples by using the flexAnalysis software and relative statistic software, and we found that the peak intensity results in Table 11. From the result shown in Table 11, we found that of the compared results from three paired groups, the highest peak intensities were from the MB-WCX group, then the MB-Cu and MB-HIC C8 groups. We did the paired samples correlation of these 24 serum samples, and got the results shown in Table 12. Finally, we did the paired samples test of the healthy control group. The result is shown below in Table 13. We found that there was no significant different in paired group MB WCX-Cu, but there was great significant difference in two paired groups, MB WCX-C8 and paired group MB Cu-C8. The p values were both <0.01. Then, we performed the peak intensities mass spectra analysis shown in Figure 8 and Figure 9. From this data, we extracted know the information of these three kinds of magnetic beads. 5. DISCUSSION Proteomic pattern analysis is one of the most promising new approaches for seeking for potential biomarkers and classifying cancer versus non-cancer samples. But, before MALDI-TOF MS analysis, we must pre-analyze all these kind of complex mixture samples-serum. Our aim of is to extract as many proteins or peptides from the serum as possible especially low abundance ones. The process of fractionation of proteins or peptides from samples is a difficult and complex process, as we know little about the real components in the mixture of serum samples. According to the characteristics of samples, we should select different methods to extract proteins or peptides for good quality and high reproducibility mass spectra. Only by doing these can we lay a good foundation for the finding of differential proteins or peptides and seeking for potential biomarkers. Proteome fractionation of serum samples is one of the most important and basic steps in proteomic analysis. If we use the wrong method to fractionate proteins and peptides from mixtures of body fluid, we could get little or no sample to analyze. In order to solve these problems, in the MALDI-TOF MS analysis, we used magnetic particles, which we called magnetic bead, a mean pore size of 40 nm, and a specific surface area of 100 cm2 /g, to extract the mixture in the serum samples, especially the low abundance proteins or peptides. This high sensitivity and reproducibility of the novel magnetic-bead-based platform gives us a good support for proteomic analysis. Some reported that use of porous particles for sample pretreatment is more sensitive than surface capture on chips, because spherical particles have larger combined surface areas than small-diameter spots. Using the magnetic bead technology, we can find more different proteome signals in the MALDI-TOF MS analysis. The application of magnetic bead fractionation in combination with MALDI-TOF is appropriate for the detection of low concentrations of proteins and peptides in serum samples. Though using a magnetic-bead-based platform is more convenient for proteomic analysis, we still have to pay special attention to the details such as what kind of magnetic bead we can choose, the real mass range we want to explore, etc. In order to solve these problems, we did our research about how to choose the right magnetic bead for breast cancer, and got some experience that can be used for reference. In our research, we chose 28 breast cancer patient serum samples as the cancer group and 24 healthy control serum samples as control group, made the pre-extraction with three kinds of magnetic beads (MB-WCX, HIC C8 and IMAC-Cu) and compared all the mass spectra results. We compared the whole quality of cancer group and normal group, the coherence in the group, the peak numbers and peak intensities in both groups and the most peaks' mass range we could get in the MALDI-TOF analysis. With the help of flexAnalysis software and statistical software, we did the data analysis and chose WCX magnetic beads as the best for our breast cancer research, since the compared quality and the coherence in both the cancer and control groups was the best of the three sets of magnetic beads. Then, we did the peak numbers and peak intensities analysis in the cancer group and control groups. In the cancer group, the average peak numbers in MB-WCX group was more than those of MB-Cu and MB-HIC C8, with great significant difference, p<0.01. But, little was found in MB-Cu and MB-HIC C8. In control group, the results were similar to the cancer group, and there was still great difference in these three groups(MB-WCX ,MB-Cu and MB-HIC C8) as p<0.01. The peak intensities' results were distinguished in the cancer group and control groups. In the cancer group, the result was similar to the average peak numbers, though the peak intensities were much higher than those of MB-Cu and MB-HIC C8. Almost none was found in MB-Cu and MB-HIC C8. The result from the control group was different from the results of average peak numbers, there was almost no difference between MB-WCX group and MB-Cu group, but significant difference was found in the two paired groups that were MB-WCX group with MB-HIC C8 and MB-Cu group with MB-HIC C8 , p<0.01. At last, we made a comparison of the mass range distribution. Because different kinds of magnetic beads have different capability in capturing proteins and peptides in chromatography, this is of fundamental importance in the MALDI-TOF MS analysis. Human serum is a very complex biological sample. We know little of the mixture of so many proteins and peptides. So at the beginning of our research design, we had to take many factors into account, and hope to get as many proteins and peptides from serum samples as possible. We had no real target data of what is useful and what is not. For this reason, the objective of pre-extraction is developed for enrichment and purification proteins and peptides in serum samples, especially low abundance ones. If we know the mass range of the aim protein, we can choose the exact kind. For example, by pre-extraction of MB-Cu, the most peaks' mass range is about 2,000-5,000 Da. For MB-HIC C8, it is about 1000-4000 Da, but we can not get much larger ones. But for MB-WCX, we will get a wide range of the mass from 1,000-10,000 Da. In our research we chose MB-WCX as the best magnetic bead for pre-extraction samples, because the research objective was to get as much as proteins and peptides as possible, so that we can obtain more information from serum samples, settle a good foundation for cancer diseases research and afford more candidate proteins and peptides for biomarker finding. Based on the above information, we chose the right magnetic bead according to the aim of the research, which will afford more convenience, save more time and get better quality origin mass spectra, so that we can improve the sensitivity and reproducibility in MALDI-TOF MS analysis. 6. ACKNOWLEDGEMENTS We would like to acknowledge Chun-xi Zhou of Bruker Daltonics Inc., Xiao-hui Hu and Ru-lei Yin of Bioyong Rnc. for the help of technical support and data analysis to this project. This work was supported by the Ministry of Science and Technology of China (2006FY230300). 7. REFERENCES 1. Shu-ling Li. Science and technology publishing company. 2000:599. NO DOI found 2. Ferlay J, Bray F, Pisani P, and Parkin,D,M. GLOBOCAN 2000. Cancer Incidence, Mortality and Prevalence Worldwide. 2001, Lyon. IARC press. NO DOI found 3. Kevin P. Rosenblatt, Peter Bryant-Greenwood, J. Keith Killian, Arpita Mehta, David Geho, Virginia Espina, Emanuel F. Petricoin III, and Lance A. Liotta. Serum proteomics in cancer diagnosis and management. Annu Rev Med 2004; 55:97-112. doi: 10.1146/annurev.med.55.091902.105237
4. Ruth Etzioni, Nicole Urban, Scott Ramsey, Martin McIntosh, Stephen Schwartz, Brian Reid, Jerald Radich, Garnet Anderson, Leland Hartwell. The case for early detection. Nat Rev Cancer 2003; 3:243-52. doi:10.1038/nrc1041
5. Gloeckler-Ries LA, Reichman ME, Lewis DR, Hankey BF, Edwards BK. Cancer survival and incidence from the Surveillance, Epidemiology, and End Results (SEER) program. Oncologist 2003; 8:541-52. doi:10.1634/theoncologist.8-6-541
6.Ahmedin Jemal, Ram C. Tiwari, Taylor Murray, Asma Ghafoor, MPH, Alicia Samuels, MPH, Elizabeth Ward, Eric J. Feuer, and Michael J. Thun,Cancer statistics, 2004. CA Cancer J Clin 2004; 54:8-29. doi: 10.3322/canjclin.54.1.8
7. Tiwari RC, Ghosh K, Jemal A, Hachey M, Ward E, Thun MJ, Feuer EJ.A new method of predicting US and state-level cancer mortality counts for the current calendar year. CA Cancer J Clin 2004; 54: 30-40.
8. Paweletz, C. P., Trock, B., Pennanen, M., Tsangaris, T, Magnant, C., Liotta, L. A., and Petricoin, E. F., 3rd (2001). Proteomic patterns of nipple aspirate fluids obtained by SELDI-TOF: potential for new biomarkers to aid in the diagnosis of breast cancer. Dis Markers, 17(4):301-7.
9. Wellmann, A., Wollscheid, V., Lu, H., Ma, Z. L., Albers, P., Schutze, K., Rohde, V., Behrens, P., Dreschers, S., Ko, Y., and Wernert, N. (2002). Analysis of microdissected prostate tissue with proteinchip arrays {away to new insights into carcinogenesis and to diagnostic tools. Int JMol Med, 9(4):341-7.
10. Petricoin, E. F., 3rd, Ornstein, D. K., Paweletz, C. P., Ardekani, A., Hackett, P. S., Hitt, B. A., Velassco, A., Trucco, C., Wiegand, L., Wood, K., Simone, C. B., Levine, P. J., Linehan, W. M., Emmert-Buck, M. R., Steinberg, S. M., Kohn, E. C., and Liotta, L. A. (2002). Serum proteomic patterns for detection of prostate cancer. J Natl Cancer Inst, 94(20):1576-8. doi:10.1093/jnci/94.20.1576
11. Adam, B. L., Qu, Y., Davis, J. W., Ward, M. D., Clements, M. A., Cazares, L. H., Semmes, O. J., Schellhammer, P. F., Yasui, Y., Feng, Z., and Wright, G. L., Jr. (2002). Serum protein fingerprinting coupled with a pattern-matching algorithm distinguishes prostate cancer from benign prostate hyperplasia and healthy men. Cancer Res, 62(13):3609-14.
12. Adam, P. J., Boyd, R., Tyson, K. L., Fletcher, G. C., Stamps, A., Hudson, L., Poyser, H. R., Redpath, N., Gri�ths, M., Steers, G., Harris, A. L., Patel, S., Berry, J., Loader, J. A., Townsend, R. R., Daviet, L., Legrain, P., Parekh, R., and Terrett, J. A. (2003).Comprehensive proteomic analysis of breast cancer cell membranes reveals unique proteins with potential roles in clinical cancer. J Biol Chem, 278(8):6482-9. doi:10.1074/jbc.M210184200
13. Zhukov, T. A., Johanson, R. A., Cantor, A. B., Clark, R. A., and Tockman, M. S. (2003). Discovery of distinct protein profiles specific for lung tumors and pre-malignant lung lesions by SELDI mass spectrometry. Lung Cancer, 40(3):267-79. doi:10.1016/S0169-5002(03)00082-5
14. Schaub, S., Wilkins, J., Weiler, T., Sangster, K., Rush, D., and Nickerson, P. (2004). Urine protein profling with surface-enhanced laser desorption/ionization time-of-flight mass spectrometry. Kidney Int, 65(1):323-32. doi:10.1111/j.1523-1755.2004.00352.x
15. Schuerenberg M, Luebbert C, Eickhoff H, Kalkum M, Lehrach H, Nordhoff E. Prestructured MALDI-MS sample supports. Anal Chem 2000;72:3436-42. doi:10.1021/ac000092a
Key Words: Magnetic bead, MALDI-TOF MS, fractionation, proteomic analysis, MB-WCX Send correspondence to: Ya-ping Tian, Department of Clinical Biochemistry, Chinese PLA General Hospital, Tel: +86 10 66939374, Fax: +86 10 88217385, E-mail:tianyp61@gmail.com |